To test a neon light transformer, you can use a "jump-out" method by bypassing the neon tube with a piece of GTO (gas tube output) wire between the wiring inlet and outlet.
Detailed Testing Procedure
Here's a breakdown of the steps involved in testing a neon light transformer:
-
Visual Inspection: First, carefully inspect the transformer for any signs of physical damage, such as cracks, burns, or loose connections. If there is visible damage, the transformer should not be used.
-
Input Voltage Check: Confirm that the input voltage is within the specified range for the transformer (typically 120V). A minimum voltage of 108V is often required for a 120V neon transformer to operate correctly. Use a multimeter to verify the input voltage.
-
"Jump-Out" Test: This is the key test described in the reference.
- Disconnect the neon tube from the transformer.
- Using a piece of GTO wire (high-voltage wire suitable for neon signs), create a direct connection ("jump") between the transformer's output terminals where the neon tube was connected. This bypasses the neon tube.
- Turn on the power to the transformer.
- If other neon tubes in the sign (if applicable) now light up brightly, it indicates that the original neon tube is defective. If the other tubes still don't light, or the transformer still appears to not be working, the transformer itself may be faulty.
-
Testing with a Multimeter (Proceed with Caution):
- Warning: Neon sign transformers generate high voltage. Extreme caution must be used when performing voltage tests. If you are not comfortable working with high voltage, consult a qualified electrician.
- Set your multimeter to measure AC voltage. The proper voltage setting depends on the voltage of the transformer - typically in the thousands of volts.
- With the transformer powered on (and the neon tube disconnected for safety reasons), carefully measure the output voltage across the transformer's output terminals. The reading should be near the transformer's rated output voltage. Do not touch the probes during measurement. If there is no output voltage, or a significantly lower voltage than expected, the transformer is likely defective.
Understanding the Test
The "jump-out" test helps determine if the problem lies with the neon tube or the transformer. If bypassing the neon tube allows other tubes to light correctly, the neon tube itself is faulty, not the transformer. If the other letters still fail to light brightly, the transformer is likely the problem.
Considerations
- Safety: Always prioritize safety when working with electricity, especially high-voltage devices like neon sign transformers.
- Professional Help: If you're unsure about any step in the testing process, consult a qualified electrician or neon sign technician.
- Transformer Ratings: Verify the transformer's input and output voltage ratings to ensure proper operation and compatibility.