What is the Formula for Loss in Optical Fiber?

Published in Optical Fiber 2 mins read

The total loss in an optical fiber link can be calculated by summing up the individual losses incurred along the fiber. Here's the breakdown of the formula:

Total Link Loss = Connector Loss + Cable Attenuation + Splice Loss

Let's elaborate on each component:

1. Connector Loss

Connectors join fiber optic cables to equipment or other cables. Each connector introduces some loss due to imperfect alignment, air gaps, or surface defects. Connector loss is typically measured in decibels (dB). The total connector loss is calculated by:

Connector Loss = Number of Connectors x Loss per Connector

For example, if you have two connectors, each with a loss of 0.5 dB, the total connector loss would be 1 dB.

2. Cable Attenuation

Cable attenuation refers to the signal loss per unit length of the fiber optic cable. It is typically expressed in decibels per kilometer (dB/km). The cable attenuation depends on the wavelength of light used and the type of fiber. The total cable attenuation is given by:

Cable Attenuation (dB) = Length (km) x Attenuation Coefficient (dB/km)

For instance, if you have 10 km of fiber cable with an attenuation coefficient of 0.3 dB/km, the total cable attenuation would be 3 dB.

3. Splice Loss

Splicing involves joining two fiber optic cables permanently. Similar to connectors, splices also introduce loss due to imperfections in the joint. Splice loss is also measured in decibels (dB). The total splice loss is calculated by:

Splice Loss = Number of Splices x Loss per Splice

For example, if there are three splices in the fiber link, each with a loss of 0.1 dB, then the total splice loss is 0.3 dB.

Putting it All Together: Example

Let's say you have an optical fiber link with the following characteristics:

  • Length: 20 km
  • Attenuation Coefficient: 0.2 dB/km
  • Number of Connectors: 2
  • Loss per Connector: 0.5 dB
  • Number of Splices: 1
  • Loss per Splice: 0.1 dB

Then, the total link loss would be:

Total Link Loss = (2 x 0.5 dB) + (20 km x 0.2 dB/km) + (1 x 0.1 dB)
Total Link Loss = 1 dB + 4 dB + 0.1 dB
Total Link Loss = 5.1 dB

Therefore, the total loss in the optical fiber link is 5.1 dB.